Drawback: Difficult to install at homes with small lots. Chamber systems are used in areas where the water table is high, alleviating the possibility for poor drainage and messy back-ups. This system also requires of a series of connected pipes and chambers where the chambers are surrounded by soil.
The septic pipes move the wastewater from the house to the septic tank and then to the chambers. In the chambers, the wastewater drains through the soil. The microbes in the soil treat the wastewater just prior to the wastewater draining away from the housing structure, releasing the treated wastewater into the soil as it travels down toward the groundwater. Benefit: Installation in areas with high water tables, or significant ground water saturation year round.
Aerobic treatment systems infuse oxygen with the wastewater inside the septic treatment tank. The infused oxygen in the wastewater helps to add nutrients to the wastewater and efficiently begin the treatment process. Aerobic systems offer tanks that both pretreat and final treat, and systems with two separate tanks for pretreatment and final treatment.
The ultimate goal is to treat and disinfect efficiently and safely. Benefit: Good for areas with high water tables or areas that lack the acreage for a proper drain field.
Drawback: Much like the drip distribution system, maintenance with an aerobic system is a must. Utilizing a snaking system of distribution pipes buried near the surface of the soil, the Drip Distribution system does not require a traditional gravel based drain field. With the drip distribution system, piping laterals are buried in shallow ground soil, typically just 6 to 12 inches below the surface.
Without the need for a traditional drain field, this system alleviates the deep digging and provides easier access to piping within the drain field. Although more convenient, the drip distribution system is more complicated than a conventional system due to the necessary precautions that must be adhered to when dispersing the wastewater into the soil absorption area. To accommodate this method, a second tank called a dose tank is needed to accept the wastewater after it passes through the septic tank.
The dose tank slowly releases the wastewater to the drip system in a timed fashion, so as not to over flow the absorption area. But the dose tank must be hooked-up to electricity to make this happen. Benefit: Lack of traditional wastewater field system. Drawback: Added expense of electricity, and additional maintenance. Sand filter systems allow waste water to flow from the septic tank to a pump chamber, and then from the pump chamber to the sand filtration system.
The sand filtration system is simply a large concrete box filled with a sand. Once the waste water is slowly pumped to the top of the box, it filters through the sand which treats the water prior to its release in the soil absorption area. Benefit: Good for areas with high water tables. Once the wastewater flows from the septic tank to the waterproof drain field, it slowly evaporates. Unlike the other septic options, the wastewater never filters into the soil. Installation, maintenance, and ease is high compared to the alternatives.
Heavy solids settle to the bottom of the tank while greases and lighter solids float to the top. The solids stay in the tank while the wastewater is discharged to the drainfield for further treatment and dispersal.
A decentralized wastewater treatment system consisting of a septic tank and a trench or bed subsurface wastewater infiltration system drainfield. A conventional septic system is typically installed at a single-family home or small business. The name refers to the construction of the drainfield. With this design, effluent is piped from the septic tank to a shallow underground trench of stone or gravel. A geofabric or similar material is then placed on top of the trench so sand, dirt, and other contaminants do not enter the clean stone.
Gravelless drainfields have been widely used for over 30 years in many states and have become a conventional technology replacing gravel systems. They take many forms, including open-bottom chambers, fabric-wrapped pipe, and synthetic materials such as expanded polystyrene media. The gravelless systems can be manufactured with recycled materials and offer a significant savings in carbon footprint.
An example of a gravelless system is the chamber system. The primary advantage of the chamber system is increased ease of delivery and construction. They are also well suited to areas with high groundwater tables, where the volume of influent to the septic system is variable e. This type of system consists of a series of connected chambers. The area around and above the chambers is filled with soil.
Pipes carry wastewater from the septic tank to the chambers. In the chambers, the wastewater comes into contact with the soil. Microbes on or near the soil treat the effluent.
The drip distribution system is a type of effluent dispersal that can be used in many types of drainfields. The main advantage of the drip distribution system is that no large mound of soil is needed as the drip laterals are inserted into the top 6 to 12 inches of soil.
The disadvantage of the drip distribution system is that it requires a large dose tank after the septic tank to accommodate the timed dose delivery of wastewater to the drip absorption area. Additional components, such as electrical power, are necessary for this system, requiring an added expense and increased maintenance. Aerobic Treatment Units ATUs use many of the same processes as a municipal sewage plant, but on a smaller scale.
These risers really make it easy to perform maintenance on the tank. There are three textures of soil—sand, silt, and clay—and they affect how fast wastewater filters into the soil called hydraulic conductivity and how big of an absorption field you need. Sand transmits water faster than silt, which is faster than clay. Sandy soils are in soil type I and clay soils are in soil type IV. A standard drain field cannot be used in a clay soil.
Also important to the design is the Hydraulic Loading, which is the amount of effluent applied per square foot of trench surface.
Because water filters through clay soils more slowly than through sand or silt, the hydraulic loading rate is lower for clay than for sand. Because clay soils have a low conductivity, only nonstandard drain fields can be used in clay. Reference: Lesikar, Bruce. Publication L Fill out my Wufoo form! For service call What size septic tank do I need? Bedrooms Home Square Footage Tank Capacity 1 or 2 Less than 1, 3 Less than 2, 1, 4 Less than 3, 1, 5 Less than 4, 1, 6 Less than 5, 1, How often should my tank be pumped?
Two critical components Standard treatment systems have two components: a septic tank and a soil absorption system. Tank The septic tank is an enclosed watertight container that collects and provides primary treatment of wastewater by separating the solids from the wastewater.
Drainfield The soil absorption field provides final treatment and distribution of the wastewater.